Severity: Warning
Message: Illegal string offset 'open'
Filename: libraries/Mybreadcrumb.php
Line Number: 8
Backtrace:
File: /www/wwwroot/japantest.vn/application/libraries/Mybreadcrumb.php
Line: 8
Function: _error_handler
File: /www/wwwroot/japantest.vn/application/core/MY_Controller.php
Line: 7
Function: __construct
File: /www/wwwroot/japantest.vn/application/controllers/Product.php
Line: 5
Function: __construct
File: /www/wwwroot/japantest.vn/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Illegal string offset 'close'
Filename: libraries/Mybreadcrumb.php
Line Number: 9
Backtrace:
File: /www/wwwroot/japantest.vn/application/libraries/Mybreadcrumb.php
Line: 9
Function: _error_handler
File: /www/wwwroot/japantest.vn/application/core/MY_Controller.php
Line: 7
Function: __construct
File: /www/wwwroot/japantest.vn/application/controllers/Product.php
Line: 5
Function: __construct
File: /www/wwwroot/japantest.vn/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Illegal string offset 'itemOpen'
Filename: libraries/Mybreadcrumb.php
Line Number: 10
Backtrace:
File: /www/wwwroot/japantest.vn/application/libraries/Mybreadcrumb.php
Line: 10
Function: _error_handler
File: /www/wwwroot/japantest.vn/application/core/MY_Controller.php
Line: 7
Function: __construct
File: /www/wwwroot/japantest.vn/application/controllers/Product.php
Line: 5
Function: __construct
File: /www/wwwroot/japantest.vn/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Illegal string offset 'itemClose'
Filename: libraries/Mybreadcrumb.php
Line Number: 11
Backtrace:
File: /www/wwwroot/japantest.vn/application/libraries/Mybreadcrumb.php
Line: 11
Function: _error_handler
File: /www/wwwroot/japantest.vn/application/core/MY_Controller.php
Line: 7
Function: __construct
File: /www/wwwroot/japantest.vn/application/controllers/Product.php
Line: 5
Function: __construct
File: /www/wwwroot/japantest.vn/index.php
Line: 316
Function: require_once
This tester is to evaluate the flammability resistance of electric wires by conducting a vertical flammability test. The operator is to fix the test specimen to the upper and lower Chuck and tilt the burner 20° to burn the test specimen for 15 seconds.
Chamber | 1.6 × 1.6 × 1.6 m (Volume Approx. 4 m3) |
---|---|
Specimen | L450 ± 10 mm |
Burner | L100 ± 10 mm, Inner Diameter φ9.5 ± 0.3 mm |
Burner Base | Inclination Angle 20° |
Burner Calibration Device |
Flow Meter: Max. 1,000 ml/min (Scale 10 ml/min) (Standard 965 ml/min) Manometer: Max. 400 (± 200) mmH2O (Scale 1 mmH2O) (Standard 125 ± 15 mmH2O) Timer, Thermometer, Slug |
Accessories | Gas Lighter, Flame Gauge, Ring Stand, Gauge for Slug, Dry Cotton Pad |
Power Source |
Tester Body: AC 100 V, 1-Phase, 3 A, 50/60 Hz Calibration Device: AC 100 V, 1-Phase, 3 A, 50/60 Hz |
Heat Source | Methane Gas (Purity: 98 % Over) |
Dimensions/ Weight (Approx.) | W1,700 × D1,700 × H2,500 mm, 380 kg (Chamber) |