Severity: Warning
Message: Illegal string offset 'open'
Filename: libraries/Mybreadcrumb.php
Line Number: 8
Backtrace:
File: /www/wwwroot/japantest.vn/application/libraries/Mybreadcrumb.php
Line: 8
Function: _error_handler
File: /www/wwwroot/japantest.vn/application/core/MY_Controller.php
Line: 7
Function: __construct
File: /www/wwwroot/japantest.vn/application/controllers/Product.php
Line: 5
Function: __construct
File: /www/wwwroot/japantest.vn/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Illegal string offset 'close'
Filename: libraries/Mybreadcrumb.php
Line Number: 9
Backtrace:
File: /www/wwwroot/japantest.vn/application/libraries/Mybreadcrumb.php
Line: 9
Function: _error_handler
File: /www/wwwroot/japantest.vn/application/core/MY_Controller.php
Line: 7
Function: __construct
File: /www/wwwroot/japantest.vn/application/controllers/Product.php
Line: 5
Function: __construct
File: /www/wwwroot/japantest.vn/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Illegal string offset 'itemOpen'
Filename: libraries/Mybreadcrumb.php
Line Number: 10
Backtrace:
File: /www/wwwroot/japantest.vn/application/libraries/Mybreadcrumb.php
Line: 10
Function: _error_handler
File: /www/wwwroot/japantest.vn/application/core/MY_Controller.php
Line: 7
Function: __construct
File: /www/wwwroot/japantest.vn/application/controllers/Product.php
Line: 5
Function: __construct
File: /www/wwwroot/japantest.vn/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Illegal string offset 'itemClose'
Filename: libraries/Mybreadcrumb.php
Line Number: 11
Backtrace:
File: /www/wwwroot/japantest.vn/application/libraries/Mybreadcrumb.php
Line: 11
Function: _error_handler
File: /www/wwwroot/japantest.vn/application/core/MY_Controller.php
Line: 7
Function: __construct
File: /www/wwwroot/japantest.vn/application/controllers/Product.php
Line: 5
Function: __construct
File: /www/wwwroot/japantest.vn/index.php
Line: 316
Function: require_once
This tester is used to evaluate the oxygen index flammability of plastic and rubber. The operator is to check the lowest oxygen level (the oxygen level is acquired from a mixture gas of oxygen and nitrogen) that the test specimen is capable to flame inside the flaming column.
Model | No.214 | No.214-ISO |
---|---|---|
Glass Column | Inner φ75 + 3 mm, H450 ± 5 mm |
Inner φ95 mm, H450 mm, Upper Seal φ40mm |
Flow Meter |
Oxygen: Max. 8.6 L/min (Scale 0.1 L/min) Flow Meter: Max. 11 L/min (Scale 0.1 L/min) |
Oxygen: Max. 20 L/min (Scale 0.1 L/min) Flow Meter: Max. 20 L/min (Scale 0.1 L/min) |
Pressure Gauge |
Oxygen: Max. 0.1 MPa (Scale 0.002 MPa) Nitrogen: Max. 0.1 MPa (Scale 0.002 MPa) Mixed Gas: Max. 0.1 MPa (Scale 0.002 MPa) |
Oxygen: Max. 0.1 MPa (Scale 0.002 MPa) Nitrogen: Max. 0.1 MPa (Scale 0.002 MPa) Mixed Gas: Max. 0.1 MPa (Scale 0.002 MPa) |
Burner | Flame L6 to 25 mm (Adjustable) | Flame L6 to 25 mm (Adjustable) |
Specimen | Plastic, Rubber and Textile | Plastic, Rubber and Textile |
Accessories | U-shape Specimen Holder, Glass Bead | U-shape Specimen Holder |
Option | Thermometer, Jig for Hoist Specimen, HighTemperature Testing Spec (HT),Oxygen Density Analyzer | Thermometer, Jig for Hoist Specimen, HighTemperature Testing Spec (HT),Oxygen Density Analyzer |
Power Source | ― | AC 100 V, 1-Phase, 5 A, 50/60 Hz |
Heat Source | Mehane Gas (Purity: 98 % Over ) or Urban Gas | Mehane Gas (Purity: 98 % Over ) or Urban Gas |
Gas Supply | Oxygen and Nitrogen | Oxygen and Nitrogen |
Dimensions/ Weight (Approx.) | W600 × D290 × H660 mm, 30 kg | W600 × D250 × H560 mm, 20 kg |