A PHP Error was encountered

Severity: Warning

Message: Illegal string offset 'open'

Filename: libraries/Mybreadcrumb.php

Line Number: 8

Backtrace:

File: /www/wwwroot/japantest.vn/application/libraries/Mybreadcrumb.php
Line: 8
Function: _error_handler

File: /www/wwwroot/japantest.vn/application/core/MY_Controller.php
Line: 7
Function: __construct

File: /www/wwwroot/japantest.vn/application/controllers/Product.php
Line: 5
Function: __construct

File: /www/wwwroot/japantest.vn/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: Illegal string offset 'close'

Filename: libraries/Mybreadcrumb.php

Line Number: 9

Backtrace:

File: /www/wwwroot/japantest.vn/application/libraries/Mybreadcrumb.php
Line: 9
Function: _error_handler

File: /www/wwwroot/japantest.vn/application/core/MY_Controller.php
Line: 7
Function: __construct

File: /www/wwwroot/japantest.vn/application/controllers/Product.php
Line: 5
Function: __construct

File: /www/wwwroot/japantest.vn/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: Illegal string offset 'itemOpen'

Filename: libraries/Mybreadcrumb.php

Line Number: 10

Backtrace:

File: /www/wwwroot/japantest.vn/application/libraries/Mybreadcrumb.php
Line: 10
Function: _error_handler

File: /www/wwwroot/japantest.vn/application/core/MY_Controller.php
Line: 7
Function: __construct

File: /www/wwwroot/japantest.vn/application/controllers/Product.php
Line: 5
Function: __construct

File: /www/wwwroot/japantest.vn/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: Illegal string offset 'itemClose'

Filename: libraries/Mybreadcrumb.php

Line Number: 11

Backtrace:

File: /www/wwwroot/japantest.vn/application/libraries/Mybreadcrumb.php
Line: 11
Function: _error_handler

File: /www/wwwroot/japantest.vn/application/core/MY_Controller.php
Line: 7
Function: __construct

File: /www/wwwroot/japantest.vn/application/controllers/Product.php
Line: 5
Function: __construct

File: /www/wwwroot/japantest.vn/index.php
Line: 316
Function: require_once

Máy kiểm tra va đập (có tủ lạnh - nhiệt độ thấp)/(nhiệt độ cực thấp) Yasuda No.258-L/ No.258-UTL
  • yasuda5.png

Máy kiểm tra va đập (có tủ lạnh - nhiệt độ thấp)/(nhiệt độ cực thấp) Yasuda No.258-L/ No.258-UTL
Model: No.258-L/ No.258-UTL

Tiêu chuẩn: JIS-K7110、K7111-1、ASTM-D256、D6110、ISO-179-1:2010、180
  • This tester enables the operator to conduct the Charpy and Izod impact tests in a low temperature condition.
  • The low temperature chamber is double-doored and the inner door is equipped with working gloves so that the temperature inside the chamber is kept constant while the operator is attaching the test specimen.

Specification

Specifications are subject to change without notice.
Temperature Range -35 °C to 60 °C (Refrigerator)
Safety Device Hammer Setting Sensor (Interlock System on the Upper Door), Acrylic Safety Cover
Additional Specifications Refer to the below table
Option Software, Electric Hammer Release Device, Torque Adjustment Device (Only for Izod)
Power Source AC 200 V, 3-Phase, 40 A, 50/60 Hz
Dimensions/ Weight (Approx.) W1,100 × D1,160 × H1,760 mm, 450 kg
Specifications are subject to change without notice.
Test method Charpy Impact Tester Izod Impact Tester
Reference standards JIS-K7111, ISO-179, ASTM-D6110 JIS-K7110, ISO-180, ASTM-D256
Capacity 0.5, 1, 2, 4, 5, 7.5, 15, 25 J 1, 2.75, 5, 11, 22 J
Lift-up angle 150° 150°
Impact speed (m/s)* 2.9, 3.8 (3.46) 3.5 (3.46)
Striking Edge Angle* 30 ± 1° (45 ± 2°) 75° (-)
Striking Edge Radius (mm)* R2 ± 0.5 (R3.17 ± 0.12) R0.8 (R0.79 ± 0.12)
Anvil-Edge Distance (mm)* 22 ± 0.2 (22 ± 0.05)
Support Length (mm)* 62 + 0.5 (101.6 ± 0.5)
Accessories Specimen setting gauge, Block gauge, Torque wrench (Izod only) Specimen setting gauge, Block gauge, Torque wrench (Izod only)

*JIS/ISO Standard Value (ASTM Standard Value)
 

  • With the same funtionality, test method compatibility and options of No.258-L, No.248-UTL can lower the chamber temperature to exterme temperatures, as low as -50℃.

Specification

Specifications are subject to change without notice.
Temperature Range -50 °C to 60 °C (Refrigerator)
Safety Device Hammer Setting Sensor (Interlock System on the Upper Door), Acrylic Safety Cover
Additional Specifications Refer to the below table
Option Software, Electric Hammer Release Device, Torque Adjustment Device (Only for Izod)
Power Source AC 200 V, 3-Phase, 30 A, 50/60 Hz
Dimensions/ Weight (Approx. W1,670 × D1,480 × H2,130 mm, 710 kg
Specifications are subject to change without notice.
Test method Charpy Impact Tester Izod Impact Tester
Reference standards JIS-K7111, ISO-179, ASTM-D6110 JIS-K7110, ISO-180, ASTM-D256
Capacity 0.5, 1, 2, 4, 5, 7.5, 15, 25 J 1, 2.75, 5, 11, 22 J
Lift-up angle 150° 150°
Impact speed (m/s)* 2.9, 3.8 (3.46) 3.5 (3.46)
Striking Edge Angle* 30 ± 1° (45 ± 2°) 75° (-)
Striking Edge Radius (mm)* R2 ± 0.5 (R3.17 ± 0.12) R0.8 (R0.79 ± 0.12)
Anvil-Edge Distance (mm)* 22 ± 0.2 (22 ± 0.05)
Support Length (mm)* 62 + 0.5 (101.6 ± 0.5)
Accessories Specimen setting gauge, Block gauge, Torque wrench (Izod only) Specimen setting gauge, Block gauge, Torque wrench (Izod only)

*JIS/ISO Standard Value (ASTM Standard Value)

 