Severity: Warning
Message: Illegal string offset 'open'
Filename: libraries/Mybreadcrumb.php
Line Number: 8
Backtrace:
File: /www/wwwroot/japantest.vn/application/libraries/Mybreadcrumb.php
Line: 8
Function: _error_handler
File: /www/wwwroot/japantest.vn/application/core/MY_Controller.php
Line: 7
Function: __construct
File: /www/wwwroot/japantest.vn/application/controllers/Product.php
Line: 5
Function: __construct
File: /www/wwwroot/japantest.vn/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Illegal string offset 'close'
Filename: libraries/Mybreadcrumb.php
Line Number: 9
Backtrace:
File: /www/wwwroot/japantest.vn/application/libraries/Mybreadcrumb.php
Line: 9
Function: _error_handler
File: /www/wwwroot/japantest.vn/application/core/MY_Controller.php
Line: 7
Function: __construct
File: /www/wwwroot/japantest.vn/application/controllers/Product.php
Line: 5
Function: __construct
File: /www/wwwroot/japantest.vn/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Illegal string offset 'itemOpen'
Filename: libraries/Mybreadcrumb.php
Line Number: 10
Backtrace:
File: /www/wwwroot/japantest.vn/application/libraries/Mybreadcrumb.php
Line: 10
Function: _error_handler
File: /www/wwwroot/japantest.vn/application/core/MY_Controller.php
Line: 7
Function: __construct
File: /www/wwwroot/japantest.vn/application/controllers/Product.php
Line: 5
Function: __construct
File: /www/wwwroot/japantest.vn/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Illegal string offset 'itemClose'
Filename: libraries/Mybreadcrumb.php
Line Number: 11
Backtrace:
File: /www/wwwroot/japantest.vn/application/libraries/Mybreadcrumb.php
Line: 11
Function: _error_handler
File: /www/wwwroot/japantest.vn/application/core/MY_Controller.php
Line: 7
Function: __construct
File: /www/wwwroot/japantest.vn/application/controllers/Product.php
Line: 5
Function: __construct
File: /www/wwwroot/japantest.vn/index.php
Line: 316
Function: require_once
This tester is the fully automatic version of the HEAT DISTORTION TESTER. The robotic mechanism enables the operator to conduct the usual heat distortion test and VICAT softening temperature test automatically. By setting the test specimen to the specimen feeder, the computer software will continuously conduct heat resistance test for a maximum of 120 samples.
Stations | 3 or 6 Stations (2 kinds) |
---|---|
Temperature Range | Max. 300 °C (Oil Bath) |
Heat-Up Speed | 120 ± 10 °C/hr and 50 ± 5 °C/hr |
Bending Stress | 1.80 MPa, 0.45 MPa |
Weight Load |
DTUL: Choose 2 types from Initial 76.5 gf to Max. 3,210 gf Option VICAT: 10 ± 0.2 N, 50 ± 1 N Option Ball Pressure: 0.4 to 2.0 N |
Displacement Measurement | Differential Transformer: Scale 1/1,000 mm, Stroke 0 to ± 2 mm |
Pressure Foot |
DTUL: R 3.0 ± 0.2 mm Option VICAT: 1.000 ± 0.015 mm2 Option Ball Pressure: φ5 mm |
Support Length | 64 ± 1 mm, 100 ± 2 mm (Standard) |
Refrigerating Device |
Water Circulating System Option: Self Contained Refrigerator *When High Temperature cooling or Test Start Temperature 20 to 23 °C |
Churning Device |
Propeller type 3 and 4 Stations: 2 Propellers 6 Stations: 3 Propellers |
Test Specimens |
40 pcs × 3 Cassettes (Total 120 pcs) *When T10 mm |
Software | Windows Compatible |
Accessories | Pressure Foot Adjustment, Specimen Holder |
Option | Silicon Oil, Safety Cover, Simultaneous Loading Device (Standard for No.148-HDA), Borosilicate Glass |
Power Source | AC 200 V, 3-Phase, 30 A, 50/60 Hz |
Air Source | 0.5MPa or More |
Dimensions/ Weight (Approx.) | W1,140 to 1,400 × D900 × H1,750 mm/ 350 to 400 kg |